Discover the future of construction with prefabricated building. Streamline your project with innovative, eco-friendly, and cost-effective solutions. Explore versatile designs and fast assembly options for homes, offices, and more. Get top-quality prefab structures for your needs. Learn about sustainability, durability, and customization.
Base Frame:Base frame is made of pressed mild steel channelThe main structural element is of 100 mm x 50 mm ''C'' channels and cross member is of ''C'' channels section size 75 mm x 40 mmSide and End Walls:Side & end frames made out of pressed sections of suitable profiles/pillars of sufficient strength with exterior wall made up of 1.8 swg M.S specially corrugated sheets9 mm particle board are used for interior walls where steel sheet are treated for corrosion resistancePanels are vertically corrugated with sheets that are continuously welded to top side & base structures so as to offer better strength to weight ratio where all gaps are sealed at edges and at seams, bottom etc to prevent ingress of moistureFlooring Systems:On bottom frame 18 mm thick plywood, bison panel/E board is fixed by means of self taping screws and PVC vinyl flooring shall be fixed on the panelsRoof:Self draining type roof is provided using 1.8 swg thick M.S. sheet with adequate roof bows Roofs are adequately cambered for draining of rain water and interior panelling is done in 9 mm particle board with adequate insulationPaint:Epoxy Zinc Phosphate primer & synthetic Epoxy paint is used for final 2 coatsCorrosion free and fire proof paintsInsulation:50 mm thick Rock wool insulation is used for walls & 50 mm thick Rock wool insulation is provided for roofAluminium Windows:Aluminium sliding type powder coated windows provided that are made of aluminium section, 5 mm thick, tinted glasses are to be fitted to itElectrical System:Portable engineers cabin provided with electrical wiring suitable for 250 volt, 50 HZ single phase AC power supply All electrical wiring are concealed where suitable copper cables are used for lighting circuits The copper cables used are of 3/19 cable for lighting circuits ISI mark & concealed PVC conduits insulated copper wire are used for wiring required to be done in PVC conduit with small size distribution board with MCB protection and to separate with main supply
Bunk HouseOur expertise lies in meeting the fabrication demands of mild steel based portable Cabin. Theseare precision fabricated at our facilities using quality tested steel and are duly welded to providebetter stability. It comprises of entry doors & windows, self-draining roof, base frame, peripheralstructure as per the requirements. Further, eight corners of these Cabin are sufficientlystrengthened to facilitate transportation, lifting and placing operations.The Other Specifications IncludeBase Frame:1. Base frame used are of pressed mild steel channel section2. Main structural element are of ‘C’ Channels 100 mm x 50 mm and cross member is of ‘C’channels section size 75 mm x 40 mmSide and End Walls:1. Side & end frames made out of pressed sections of suitable profiles/pillars of sufficientstrength2. 8 mm MDF board used for interior walls3. All steel sheets used are treated for corrosion resistance4. Vertically corrugated Sheet Panels that are continuously welded to top side and basestructures to offer better strength to weight ratio5. All gaps sealed at edges & at seams, bottom etc for preventing ingress of moistureFlooring Systems:1. Bottom frame provided of 18 mm thick plywood, bison panel/E board (fixed by means of selftapingscrews)2. PVC vinyl flooring fixed on panelRoof1. Interior panelling is done in 8 mm MDF board with adequate insulationPaint:1. Epoxy Zinc Phosphate primer and synthetic Epoxy paints used for final 2 coats (Corrosion freeand fire proof paints)Insulation:1. 25 mm thick Glass wool insulation used for walls as well as 50 mm thick Glass wool insulationprovided for roofInner Panelling:1. Aesthetically finished Interiors that provide custom built appearance with high qualityworkmanship2. All vertical & horizontal corners neatly and smoothly finished with Aluminium sections3. Panelling of side walls & roof is of 8 mm thick decorative laminated MDF boardMain Entry Door:1. The door interiors finished with same material matching with that of bunk house interiors2. Doors provided with locking arrangement with separate handles of both sides of door asrequiredAluminium Windows:1. Aluminium sliding type powder coated windows that are made of aluminium section which is 4mm thick tinted glass.Electrical System:1. Bunk houses provided with concealed electrical copper cables & wiring suitable for 250 volt,50 HZ single phase AC power supply2. Copper cables used are of 3/19 cable for lighting circuits3. ISI mark & concealed PVC conduits insulated copper wire used for wiring in PVC conduit withsmall size distribution board with MCB protection and to separate with main supply.
if you are interested, please fill the below details: